MT-4E ANALOG & P25 DIGITAL RADIO SYSTEMS | MAINTENANCE GUIDE
Chapter 2: Installation Page 5
CHAPTER 2: INSTALLATION
INSTALLATION OF CODAN SUBRACKS
1. Ensure the 19” rack has enough room for the Codan subrack to be installed. Each Codan subrack
requires 5 1/4” height (3 RU) and 13.5” (maximum) depth clearances.
2. Install the subrack unit(s) in the 19” rack using four #10 x 3/4” screws as shown in Figure 2-1. Eight
screw holes are available, only four screws are required to mount the subrack properly. Use stainless
steel screws if the equipment is to be placed in a corrosive environment.
Figure 2-1: Subrack Installation
#10 x 3/4”
screws